Working with Config Automation
Learn how to work with Config Automation.
To create Config RFC:
- Click the Config Automation tab, and then under the RFC listing, click Initiate Config Activity.The Activity Details page opens.
- For Config Type, select Trace & Debug.
- For Activity Name, select either of the following:
- FRD Enable/Disable (applicable only for Apps Version - Pre 12.2 )
- FND Enable/Disable
If FRD Enable/Disable is selected, then the Bounce check box is visible. Select the check box to enable Bounce.
- For Activity Type, select Enable.
- Select a Target.
- For Summary, optionally enter a summary of this RFC.
- Select Auto Disable Interval to schedule the disable activity time gap.
- In the Activity Based Inputs section, enter the UserName.
- If FND Enable/Disable is selected, enter Debug Log Module, and select Debug Log Level.
- Select the Accept Risk check box.
- Click Customer Note to add an action plan or any other relevant information you want included in the RFC.
- Click Create RFC, schedule it, and go back to Dashboard.RFC information appears in the RFC list. Based on the Auto- Disable Interval you selected, Disable RFC will be auto-created.
- After enabling Activity, proceed to simulate the step using EBS UI.
- Under Dashboard, click Update.The Update feature allows you to initiate the transfer of logs (assuming that you already simulated the EBS steps).