Checking if a Volume Attachment is Multipath-Enabled
When you attach a volume configured for the Ultra High Performance level, the volume attachment must be enabled for multipath to optimize the volume's performance. This topic describes how to verify if the volume attachment is multipath-enabled.
If the volume attachment is not multipath-enabled, but the volume's performance level is
configured for Ultra High Performance, see Troubleshooting Ultra High Performance Volume Attachments for steps you can take to address
the issue.
Using the Console
You can check whether a volume attachment is multipath-enabled in the Console from the
Volume Details page or the Instance Details page.
From the Volume Details Page
Open the navigation menu and click Storage. Under Block Storage, click Block Volumes.
Click the block volume that you want to check the volume attachment for.
Click Attached Instances in the Resources section.
Check the value displayed in the Multipath column.
Yes: The volume is configured for the Ultra High Performance level and the volume
attachment is multipath-enabled. No further action is required.
No: The volume is not configured for the Ultra High
Performance level, the volume does not need to be
multipath-enabled. No further action is required.
No with a warning icon: The volume is configured for the Ultra
High Performance level, but the volume attachment is not
multipath-enabled. To achieve optimal performance, you need to ensure
the volume is attached to a supported instance shape, and that the
required prerequisites are configured.
From the Instance Details Page
Open the navigation menu and click Compute. Under Compute, click Instances.
Click the instance that you want to check the volume attachment for.
Click Attached Block Volumes in the Resources section.
Check the value displayed in the Multipath column.
Yes: The volume is configured for the Ultra High
Performance level and the volume attachment is
multipath-enabled. No further action is required.
No: The volume is not configured for the Ultra High
Performance level, the volume does not need to be
multipath-enabled. No further action is required.
No with a warning icon: The volume is configured for the
Ultra High Performance level, but the volume attachment
is not multipath-enabled. To achieve optimal performance, you need
to ensure the volume is attached to a supported instance shape, and
that the required prerequisites are configured.
The following image shows the multipath column in the Console.
Using the CLI 🔗
For information about using the CLI, see Command Line Interface (CLI). Use the volume-attachment get operation to check whether the volume attachment is multipath-enabled.
Open a command prompt and run:
Command
CopyTry It
oci compute volume-attachment get --volume-attachment-id <volume-group-ID>
For example:
Command
CopyTry It
oci compute volume-attachment get --volume-attachment-id ocid1.volumeattachment.oc1.phx.<unique_ID>
The is-multipath property will be true for multipath-enabled
attachments; false for attachments that are not multipath-enabled.
Using the API 🔗
To check whether the volume attachment is multipath-enabled, use the following
operation: